Maytag 23inch Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Nein Maytag 23inch herunter. Maytag 23inch Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
is a registered trademark of Maytag Corporation or its related companies
and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved.
Room Air Conditioner & Heat Pump
Use and Care Manual
Introduction
Room air conditioners cool, dehumidify, and filter air inside
your home. Heat pump and electric heat models offer both
heating and cooling. Opening sections of manual provide
general information for all room air conditioner models.
Operating Controls section describes operation of controls
for each model. After reading the opening sections, turn to
Operating Controls section and find the panel layout that
matches the model of your unit.
Read entire manual thoroughly before beginning installation
and operation of your new room air conditioner. Be sure you
have all necessary tools and materials on hand for the job.
Study illustrations to familiarize yourself with important
details of the installation process. Review manual for oper-
ating instructions.
NOTE
1. Mechanical experience is required to install air condi-
tioner.
2. Installation can take from 1 to 3 hours, depending on
installer’s knowledge and skill.
3. If you encounter problems during installation, call our
consumer information line toll-free at 1-877-376-0214. If
your problem cannot be resolved by phone, contact an
authorized Amana
®
brand servicer. Contact and service
will be at your expense.
Safety Information
Be sure electrical service is adequate for chosen model of air
conditioner. Complete electrical rating for unit is found on
serial plate located behind front grille. Electrical outlet must
be close enough to unit for power cord to reach without strain.
Air conditioner should be the only appliance on individual
circuit.
For personal safety and to avoid possible damage to appli-
ance or home, observe all safety instructions highlighted by
symbol shown below.
RECOGNIZE THIS SYMBOL AS A
SAFETY PRECAUTION.
After installing unit, reread instructions to ensure each step
is complete and that all parts are fastened in place. For best
results and to minimize installation time, perform all proce-
dures in the order shown.
WARNING
HIGH VOLTAGE
Disconnect ALL power before
servicing or installing this unit.
Multiple power sources may be
present. Failure to do so may cause
property damage, personal injury,
or death.
IO-371A
©2010 Goodman Company, L.P.
Effective: May 2010
Contents
Introduction .................................................................. 1
Safety Information ....................................................... 1
Unpacking .................................................................... 2
Electrical Requirements.............................................. 2
Installation ................................................................... 3
Room Heat Pumps ....................................................... 3
Normal Care & Maintenance ...................................... 3
Installation Requirements ........................................... 5
Installation Instructions ............................................... 8
General Instructions .................................................. 13
Through-The-Wall Installation Instructions ............. 14
Operating Controls .................................................... 17
Before Calling Service .............................................. 19
When Service Is Required ........................................ 19
Any Questions? .......................................................... 19
Warranty..................................................................... 20
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - Use and Care Manual

is a registered trademark of Maytag Corporation or its related companiesand is used under license to Goodman Company, L.P., Houston, TX. All rights

Seite 2 - Unpacking

104. Use a ³⁄₁₆" drill bit to drill 3 st arter holes 1/2" deep through the 3 holes in the cabinet and into the windowsill. 5. Attach cabine

Seite 3 - Normal Care and Maintenance

11Option 1 —Wood, metal or plastic moldingWhen you are using wood, metal or plastic molding, the wood frame should line up with inside wall as shown.

Seite 4 - 240 pounds

12Complete InstallationNOTE: Handle air conditioner gently.WARNING%XCESSIVE7EIGHT(AZARD5SETWOORMOREPEOPLETOMOVEANDINSTALLAIRCONDITIONER&

Seite 5 - INSTALLATION REQUIREMENTS

13While operation of all units is similar, controls vary slightlyfrom model to model. Operating Controls section showscontrol panel of unit purchased

Seite 6

14Thru-wall Installation Instructions for Amana® Brand Room Air ConditionerIntroductionThis instruction sheet provides guidelines for installing acomp

Seite 7 - Power Supply Cord

15In order to reinstall the chassis and re-attach the air conditioner front cover, theinstalled outercase must be square and level from side to side.

Seite 8 - INSTALLATION INSTRUCTIONS

16Caulk allsidesLintel andflashing(if required)Outercase must projecta minimum ¾" beyond inside wallor molding to attach front frame93/8"wit

Seite 9 - Install Cabinet into Window

17Operating ControlsOperating your air conditioner properly helps you to obtain thebest possible results.This section explains proper air conditioner

Seite 10 - Complete Window Installation

18How to set:Press the DELAY 1-24 hr pad on the unit or the padon the remote control. Each touch of the INCREASE / DECREASE  pads on the unit

Seite 11 - Install Wood Frame

19The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause andsuggested remedies are give

Seite 12 - Complete Installation

2OWNER'S PRODUCT IDENTIFICATIONMODEL NUMBERSERIAL NUMBERMANUFACTURING NUMBEROwner's NameAddressCity State Zip / / Date of Pu

Seite 13 - Drain Cup

20 is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX. All righ

Seite 14 - Brand Room Air Conditioner

21 is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX. All righ

Seite 15 - Masonry Construction

22THIS PAGE LEFT INTENTIONALLY BLANK

Seite 16 - Installed Case

23THIS PAGE LEFT INTENTIONALLY BLANK

Seite 17 - Operating Controls

24© 2010 Goodman Company, L.P. is a registered trademark of Maytag Corporation or its related companies and is used underlicense to Goodman Company, L

Seite 18

3NEMA No. 5-15P NEMA No. 5-15R 125V-15AMP 115VNEMA No. 6-15P NEMA No. 6-15R 250V-15AMP 230/208V ratedat 12 amperes orlessNEMA No. 6-20P NEMA No. 6-20R

Seite 19 - Any Questions?

4Note: The life of your unit may be greatly reduced if you livein a salt air or other corrosive type environment. Under theseconditions, the unit sh

Seite 20 - CONSUMERS

5INSTALLATION REQUIREMENTSTools and PartsGather the required tools and parts before starting installation. Read and follow the instructions provided w

Seite 21 - (to include labor) any

6Window installation Window opening measurements: 27" min. to 39" max. (68.6 cm to 99 cm) opening width. 16¹⁄₄" min. (41.3 cm) openi

Seite 22

7Recommended grounding methodThis air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 pron

Seite 23

8INSTALLATION INSTRUCTIONSp%XCESSIVE7EIGHT(AZARD5SETWOORMOREPEOPLETOMOVEANDINSTALLAIRCONDITIONER&AILURETODOSOCANRESULTINBACKO

Seite 24 - © 2010 Goodman Company, L.P

9Attach Side Curtains1. Locate provided bag of screws. 2. Insert top and then bottom of right-hand curtain housing in top and bottom curtain guides on

Kommentare zu diesen Handbüchern

Keine Kommentare