Countertop CommercialMicrowaveOvensThis Base Manual covers general informationRefer to individual Technical Sheet for information on specic modelsTh
10 16400009 ©2010 ACP Inc.When you get a complaint from customers, evaluate the complaint carefully. If the following symptoms apply, instruct the cus
©2010 ACP Inc. 16400009 11Troubleshooting Procedures (Electronic Models)Trouble 1: Oven does not operate at all, no inputs can be accepted.CONDITIO
12 16400009 ©2010 ACP Inc.Troubleshooting Procedures (Electronic Models)Trouble 2: Display shows all gures selected, but does not start cooking even
©2010 ACP Inc. 16400009 13Trouble 3: No microwave when fan motor operates.Troubleshooting Procedures (Electronic Models)CONDITION CHECK RESULTCheck
14 16400009 ©2010 ACP Inc.Troubleshooting Procedures (Electronic Models)Trouble 4: The following visual conditions indicate a probable failed control
©2010 ACP Inc. 16400009 15Trouble 1: Oven does not operate at all, no inputs can be accepted.Troubleshooting Procedures (Dial Models)When you get
16 16400009 ©2010 ACP Inc.Troubleshooting Procedures (Dial Models)Does the oven lamp light?YESYESContinuityDoes the fan motor work when you shut the d
©2010 ACP Inc. 16400009 17Troubleshooting Procedures (Electronic Dial Models)When you get a complaint from customers, evaluate the complaint careful
18 16400009 ©2010 ACP Inc.Troubleshooting Procedures (Electronic Dial Models)CONDITION CHECKCheck continuity of magnetronDefectivemagnetronRESULTNoCon
©2010 ACP Inc. 16400009 19Troubleshooting Procedures (Electronic Dial Models)Trouble 3: No microwave oscillation even though oven lamp turns on.COND
2 16400009 ©2010 ACP Inc.Important Notices for Servicers and ConsumersMaytag will not be responsible for personal injury or property damage from impro
20 16400009 ©2010 ACP Inc.Troubleshooting Procedures (Electronic Dial Models)Trouble 4: The following visual conditions indicate a probable defective
Service Information !WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor before
Microwave Leakage Testing !WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor b
Troubleshooting !WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor before serv
Testing Procedures !WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor before ser
Testing Procedures !WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor before ser
Testing Procedures !WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor before ser
Disassembly ProceduresTo avoid the risk of electrical shock, personal injury, or death, disconnect power to oven and discharge the capacitors before f
Disassembly ProceduresTo avoid the risk of electrical shock, personal injury, or death, disconnect power to oven and discharge the capacitors before f
Disassembly ProceduresTo avoid the risk of electrical shock, personal injury, or death, disconnect power to oven and discharge the capacitors before f
©2010 ACP Inc. 16400009 3Important Information ... 2Important Safety Information ...
Disassembly ProceduresTo avoid the risk of electrical shock, personal injury, or death, disconnect power to oven and discharge the capacitors before f
Disassembly ProceduresTo avoid the risk of electrical shock, personal injury, or death, disconnect power to oven and discharge the capacitors before f
Disassembly ProceduresTo avoid the risk of electrical shock, personal injury, or death, disconnect power to oven and discharge the capacitors before f
Important Safety Information4 16400009 ©2010 ACP Inc.Read the following information to avoid possible exposure to microwave radiation:The basic design
Important Safety Information©2010 ACP inc. 16400009 5Recognize this symbol as a SAFETY messageSAVE THESE INSTRUCTIONS1. READ all instructions before
Important Safety Information6 16400009 ©2010 ACP Inc.1. Briskly stir or pour liquids before heating with microwave energy to prevent spontaneous boi
Important Safety Information©2010 ACP inc. 16400009 7Precautions to be observed before and during servicing to avoid possible exposure to excessive m
Important Safety Information8 16400009 ©2010 ACP Inc.Servicing of Grounded ProductsThe standard accepted color coding for grounding wires is GREEN or
©2010 ACP Inc. 16400009 9General InformationUnpacking Equipment • Inspectequipmentfordamagesuchasdentsindoorordentsinsideovencavity.•