The ERC is capable of detecting certain failures within the control, temperature sensor and door latch.
NOTE:
Refer to the appropriate Service Manual for detailed service instructions
.
Fault
Code
Problem Component(s) to Check
DOOR
displayed
when baking
or broiling
Door latched, failed latch switch, or short in wiring ............ Ensure door is not latched, check latch
switch connections and ohm wiring.
If ok, replace latch switch.
DOOR
displayed
when
cleaning
Door latch open, failed latch switch, open wire in circuit.... Ensure door is latched, check latch
switch connections and ohm wiring.
If ok, replace latch switch.
LOCK
displayed
when NOT
cleaning
Failed latch switch or shorted wire lead ............................. Check latch switch connections and
ohm wiring.
If ok, replace latch switch.
F1 Shorted or sticking key (button)/failed mylar touch pad ..... Check glass alignment, key (button)
movement/continuity of mylar pads.
F2 Oven cavity over temperature ............................................ Check sensor resistance and wiring.
F3 Open sensor or sensor circuit ............................................ Check sensor resistance and wiring.
F4 Shorted sensor or sensor circuit ........................................ Check sensor resistance and wiring.
F5 Failed component in ERC system...................................... Check all components and wiring.
If ok, replace control.
F6 Failed component in ERC system or fluctuation in 60Hz
power source......................................................................
Check power source before replacing
control.
F7 Shorted or sticking key (button), door lock switch failure
with door locked .................................................................
Check glass alignment, key (button)
movement. Check switch connections
and wiring. If ok, replace switch.
F8 Failed component in ERC system...................................... Check all components and wiring.
If ok, replace control.
F9 Door latch supervisory circuit problem ...............................
Door lock switch failure with door locked ...........................
Check door switch(s).
Check switch connections and wiring.
If ok, replace switch.