Jenn-Air, Maytag and Magic Chef Fault Codes
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas supply to oven before
servicing, unless testing requires power and/or gas.
©2004 Maytag Services
16023509 9
PRODUCT(S): SLIDE-IN RANGES AND WALL OVENS, JENN-AIR, EMPLOYING
POWER RELAY BOARD SYSTEM
MODEL YEAR(S): PRIOR TO 1997
Fault
Code
Problem Component(s) to Check
F1 Element relay energized in non cook mode................. J2 harness shorted. If ohms ok, change power
relay board.
DOUBLE OVEN ONLY: Change 2
nd
oven board.
F2 Oven temperature above 620˚ F in a non self clean
mode or over 950˚ F in a self clean mode ...................
Ohm sensor (see Table 4), harness, and check
door lock.** If ok, change power relay board.
F3 Cooling fan on in time of day mode ............................. Ohm sensor and harness** (see Table 4).
F4 Shorted oven sensor .................................................... Ohm sensor and harness** (see Table 4).
F5 No power to element relay in cook mode..................... Intermittent sensor or wire harness connection.
TECH TIP: Flick the sensor when checking ohms.
Look for no resistance.
Intermittent contact on power relay board.
F7 Shorted key sensed for 32 seconds............................. Membrane shorted.
Display board.
F8 Shorted meat probe ..................................................... Probe jack/harness to probe jack (see Table 3).
F9 Door lock safety circuit on relay board......................... Check door lock circuit. If ok, replace power
relay board.
FF Invalid temperature reading on power relay board ...... Check sensor (see Table 4), harness, and power
relay board.**
F &
FC***
Communication error between board........................... Ohm J2 harness wires end to end.* If ok,
replace power relay board. If blue and orange
wires tangled, untangle. If repeat code, use a
noise suppressor, part # 12001500.
FR Second oven error sensed........................................... J2 harness, ohm wires end to end.* If harness is
ok, replace power relay board. If blue and orange
wires are tangled, untangle. If repeat code, use a
noise suppressor, part # 12001500.
No display on clock: Voltage from J1-1 to J1-2 should be 13 VDC. Voltage from J1-3 to J1-4 should be 21.2 VAC.
NOTES: * Disconnect and reconnect power. If clock does not resume time (displays 12:00), replace main board.
** Sensor resistance at room temperature should be between 1050 – 1100 ohms.
*** If this occurs on SVE47500 units, refer to the U&C manual to operate the grill.
Table 3: Jenn-Air Wall Ovens and Slide-In Ranges Meat Probe Resistance
Meat Probe Resistance
Degrees F (C) Resistance
122 (50) 18963
150 (65.5) 9938
156.2 (69) 8846
165.2 (74) 7456
210.1 (98.9) 3886
Table 4: Jenn-Air Wall Ovens and Slide-In Ranges Oven Sensor Resistance
Oven Sensor Resistance
Degrees F (C) Resistance
100 (37.7) 1143
200 (93.3) 1350
300 (148.8) 1553
350 (176.6) 1654
400 (204.4) 1753